Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("CRYOGENIC CIRCUIT")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 133

  • Page / 6
Export

Selection :

  • and

QUARTZ CRYSTAL OSCILLATOR AT VERY LOW TEMPERATURE.MOSSUZ G; GAGNEPAIN JJ.1976; CRYOGENICS; G.B.; DA. 1976; VOL. 16; NO 11; PP. 652-656; BIBL. 13 REF.Article

CRYOGENIC X-BAND FERRITE PHASE SHIFTER/ATTENUATORMANN LD; BLAIR DG.1983; JOURNAL OF PHYSICS E: SCIENTIFIC INSTRUMENTS; ISSN 0022-3735; GBR; DA. 1983; VOL. 16; NO 2; PP. 119-121; BIBL. 4 REF.Article

ELECTRICAL PROPERTIES OF AN INPUT-OUTPUT CABLE FOR JOSEPHSON APPLICATIONSANDERSON CJ.1982; REVIEW OF SCIENTIFIC INSTRUMENTS; ISSN 0034-6748; USA; DA. 1982; VOL. 53; NO 11; PP. 1663-1666; BIBL. 10 REF.Article

LOW-NOISE 10.7 GHZ GAAS FET AMPLIFIERTOMASSETTI G; WEINREB S; WELLINGTON K et al.1981; ELECTRON. LETT.; ISSN 0013-5194; GBR; DA. 1981; VOL. 17; NO 25-26; PP. 949-951; BIBL. 4 REF.Article

A CRYOGENIC MILLIMETER-WAVE SCHOTTKY-DIODE MIXERKOLLBERG EL; ZIRATH HHG.1983; IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES; ISSN 0018-9480; USA; DA. 1983; VOL. 31; NO 2; PP. 230-235; BIBL. 13 REF.Article

AN SIS RECEIVER FOR THE 3 MM WAVELENGTH RANGEBLUNDELL R; HEIN H; GUNDLACH KH et al.1982; INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES; ISSN 0195-9271; USA; DA. 1982; VOL. 3; NO 6; PP. 793-799; BIBL. 8 REF.Article

A LOW-NOISE PELTIER-COOLED FET AMPLIFIERASKEW RE; WOLKSTEIN HJ.1981; RCA REV.; ISSN 0033-6831; USA; DA. 1981; VOL. 42; NO 4; PP. 661-671Article

CRYOGENIC PARAMETRIC AMPLIFIER NOISE PERFORMANCE AT 4.2 KWILSON WJ; DICKMAN RL; BERRY GG et al.1980; I.E.E.E. TRANS. MICROWAVE THEORY TECH.; USA; DA. 1980; VOL. 28; NO 3; PP. 186-190; BIBL. 14 REF.Article

Thermal performance of the CEBAF hall a cryogenic systemSCHNEIDER, W. J; FOLTS, E; MILLER, J et al.Advances in cryogenic engineering. 1996, Vol 41, pp 669-676, issn 0065-2482, AConference Paper

Glass low power closed-cycle cryo-refrigerator for long term operationengENGELLAND, W; KOSE, V.Cryogenics (Guildford). 1990, Vol 30, Num 12, pp 1074-1078, issn 0011-2275Article

Qualification and cryogenic performance of cryomodule components at CEBAFHECKMAN, J; MACHA, K; FISCHER, J et al.Advances in cryogenic engineering. 1996, Vol 41, pp 655-661, issn 0065-2482, AConference Paper

The ratio error of the overlapped-tube cryogenic current comparatorSEPPÄ, H.IEEE transactions on instrumentation and measurement. 1990, Vol 39, Num 5, pp 689-697, issn 0018-9456Article

Fast cryodetector and SQUID read-out for mass spectrometryUCHAIKIN, S. V; CHRIST, P; PRÖBST, F et al.Physica. C. Superconductivity and its applications. 2002, Vol 367, Num 1-4, pp 295-297Article

WOLTE 3 European Workshop on Low Temperature ElectronicsBROGIATO, Luciana; CAMIN, Daniel V; PESSINA, G et al.Journal de physique. IV. 1998, Vol 8, Num 3, issn 1155-4339, 331 p.Conference Proceedings

Cryogenic performance of a CMOS 32-bit microprocessos subsystem built on the silicon-substrate-based multichip packaging technologyLIN, M. S; PATERSON, A. S; GHAFFARI, H. T et al.Electronics Letters. 1990, Vol 26, Num 14, pp 1025-1026, issn 0013-5194Article

Cryogenic motorized waveguide switchKAMINSKY, P. G; RUPP, L. W. JR; YURKE, B et al.Review of scientific instruments. 1987, Vol 58, Num 5, pp 894-895, issn 0034-6748Article

Gekühlte, rauscharme Empfänger im Bereich von 140 bis 200 GHz = Récepteurs cryogéniques à faible bruit dans un domaine de fréquence de 140 à 200 GHz = Cryogenic low noise receivers in the range of 140 to 200 GHzSCHÄREN, B.Mitteilungen der Arbeitsgemeinschaft für elektrische Nachrichtentechnik der Stiftung Hasler-Werke Bern. 1984, Num 39, pp 33-37Article

Méthodologie de conception d'oscillateurs microondes cryogéniques à base de transistors à effet de champ = Design methodology for cryogenic microwave oscillators based on field effect transistorsVERDIER, J; LLOPIS, O; GRAFFEUIL, J et al.Journées nationales microondes. 1997, pp 266-267, 2VolConference Paper

High Q tunable sapphire loaded cavity resonator for cryogenic operationBLAIR, D. G; SANSON, A. M.Cryogenics (Guildford). 1989, Vol 29, Num 11, pp 1045-1049, issn 0011-2275Article

Cryogenic coil for glow discharge sourcesOHORODNIK, S. K; HARRISON, W. W.Analytical chemistry (Washington, DC). 1993, Vol 65, Num 18, pp 2542-2544, issn 0003-2700Article

Cryogenic vacuum high frequency probe stationLASKAR, J; KOLODZEY, J.Journal of vacuum science and technology. B. Microelectronics processing and phenomena. 1990, Vol 8, Num 5, pp 1161-1165, issn 0734-211XArticle

A high-performance N-MOS adder designed for optimized cryogenic operationGLORIES, P; BOUDOU, A; L'ECUYER, Y et al.IEEE journal of solid-state circuits. 1986, Vol 21, Num 3, pp 404-410, issn 0018-9200Article

A conduction-cooled, 680-mm-long warm bore, 3-T Nb3Sn solenoid for a Cerenkov Free Electron LaserWESSEL, W. A. J; DEN OUDEN, A; KROOSHOOP, H. J. G et al.IEEE transactions on applied superconductivity. 1999, Vol 9, Num 2, pp 386-389, issn 1051-8223, 1Conference Paper

Conception, réalisation et mesures d'un amplificateur cryogénique faible bruit et faible consommation sur la bande 8-12 GHz = Design, realization and characterization of a low consumption, low noise cryogenic amplifier at 8 - 12 GHzBOUTEZ, C; CROZAT, P; DANELON, V et al.Journées nationales microondes. 1997, pp 500-501, 2VolConference Paper

Aspetti relativi alla sicurezza dei lavoratori nella risonanza magnetica ad uso clinico = Safety of workers in NMR clinical plantsVIGNATI, M.Annali dell' Istituto superiore di sanità. 1994, Vol 30, Num 1, pp 109-118, issn 0021-2571Article

  • Page / 6